• If your rotor assembly impeller and internal pump body have
excessive scale build-up, clean with a mild acid, such as
white vinegar or non-abrasive calcium, lime and rust remover
product, using a sponge or soft-bristled brush that won't
scratch the stainless steel. removing scale build-up will allow
your pump to run like new again.
1
3
• When re-assembling the pump, be sure to align the raised
key on the impeller flange to the matching notch in the face
of the pump flange.
45015.110177
8
2
4
For more information about our company or products, please visit our website at www.aquascapeinc.com
or call us at (US) 1-866-877-6637 (CAN) 1-866-766-3426
©2012 Aquascape, Inc. • All Worldwide Rights Reserved
☎
US 1-866-877-6637 |
• Winter Storage – If concerned about possible freeze
damage, disconnect the threaded collar on the fitting and
remove the pump from the filter (be careful not to lose the flat
rubber washer). Clean the pump and inlet screens with fresh
water and store the pump in a frost-free location. the pump
can be run during freezing weather, if desired, but the pump
should be removed in the event of a power failure to prevent
any freeze damage to either the pump or the piping.
trOUbleShOOting
• Reduced Water Flow
– pump or plumbing may be clogged. it may be
necessary to clean the filter screens and impeller.
• Pump Hums and Doesn't Push Water
– pump or plumbing may be clogged. it may be
necessary to clean the filter screens and impeller
– remove the water chamber cover and inspect and
clean the impeller rotor assembly and internal pump
body
– Make sure nothing is blocking or wrapped around the
impeller.
– Make sure the pump is receiving the correct voltage.
• Pump Not Working
– the ground-fault circuit-interrupter (gfCi) may
have tripped
– the pump is not receiving the correct voltage.
– remote Control Not working
– Check to make sure the switch located on the receiver
is in the remote Control position.
– Check the label on the back of the receiver and
transmitter to make sure they are paired to the same
frequency.
– Check to make sure the battery is installed properly.
replace battery if needed.
.
☎