Preparation:
To connect this jig, remove the lower back cover as instructed on disassembly for service section on this service manual and insert the jig into A15 connector located on the A-Board.
Procedure to copy data:
1.
Enter to service mode and display service menu.
2.
Select "AREA" DAC and then press ACTION button on remote to enter. Press VOL right/left to select one of the following options then press ACTION:
Select ALL to copy all main EEPROM data
Select ADJ to copy only adjustment data.
Select FIX to copy only fix data
3.
To copy data from main EEPROM to jig, select "IN→EX" DAC and press ACTION button on remote.
4.
To copy data from jig to main EEPROM, select "EX→IN" DAC and press ACTION button on remote.z
10 Back cover removal
11 Chassis service adjustment procedures
All service adjustments are factory preset and should not require change unless controls and/or associated components are replaced.
140.0_V B+ voltage check
1.
Set the BRIGHT and PICTURE to minimum by using the PICTURE menu.
2.
Connect the DVM on TPD50 (D-Board by and cold ground