How To Use:
① Firmly fix adapter (for drum can) to the mouth piece(G2) on a drum can.
(Apply the attached special tool)
② Firmly fix pressing nut. (Apply the attached special tool)
③ Seal ventilation mouth on a drum can (Smaller mouth placed on a top plate).
Connect the air hose from compressor to air valve(20PM)
④
Dia.of air hose should be larger than 3/8 inches.
This pump can be operated with the supplying air pressure of 0.4~0.6MPa.
⑤
Open air-valve, and supply the compressed air to the pump
⑥
Keep the sucking pump under the liquid, then the pump starts sucking.
⑦
Once a drum becomes full of liquid, floating ball automatically works to stop
sucking.
⑧ Close air valve.
In case sucking power is not strong enough, apply air adjusting thread
⑨
attached.You can change with hexagon wrench (a two surface width: 4mm)
【Photo-1 Reference】
As air consumption volume increases, according to the sucking volume.
Please refer to Performance Curving Graph herewith (Photo-1)