Panasonic BM-ET300AE Gebruiksaanwijzing - Pagina 14
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Panasonic BM-ET300AE. Panasonic BM-ET300AE 35 pagina's. Iris camera
SPECIFICATIONS OF WIEGAND CONNECTORS (FOR CARD READER)
Pin No.
Port Name
1
POWER
2
GND
3
DATA 0
4
DATA 1
SPECIFICATIONS OF WIEGAND CONNECTORS (FOR ACCESS CONTROL PANEL)
Pin No.
Port Name
6
POWER
7
GND
8
DATA 0
9
DATA 1
Note: This port is for wiring designation convenience only.
SPECIFICATIONS OF ALARM OUTPUT CONNECTORS
Pin No.
Port Name
OUTPUT
16
ACCEPT
OUTPUT
17
REJECT
OUTPUT
18
POWER
DETECTION
OUTPUT
19
TAMPER
DETECTION
20
GND
Note: The Wiegand communication settings are made with the administration software. Refer to system administrators.
14
I/O
Signal Description
OUT
Wiegand 5 V
–
Wiegand GND
IN
Wiegand DATA 0
IN
Wiegand DATA 1
I/O
Signal Description
IN*
Wiegand 5 V
–
Wiegand GND
OUT
Wiegand DATA 0
OUT
Wiegand DATA 1
I/O
Signal Description
Recognition result output 1
OUT
(recognition ACCEPT)
Recognition result output 2
OUT
(recognition REJECT)
Alarm output 1
OUT
(power status)
Alarm output 2
OUT
(tamper detection)
Alarm output
–
(COMMON)
Remarks
5 V, 100 mA (Max)
0 V
0 V to 5 V, 24 mA (Max), Wiegand I/F
Active low
0 V to 5 V, 24 mA (Max), Wiegand I/F
Active low
Remarks
5 V
0 V
0 V to 5 V, 24 mA (Max), Wiegand I/F
Active low
0 V to 5 V, 24 mA (Max), Wiegand I/F
Active low
Remarks
Open collector output
Normally Open contact
Open collector output
Normally Open contact
Open collector output
Normally Closed contact
Open collector output
Normally Open contact
0 V for ALARM OUTPUT