HP ProCurve 1600M Installatiehandleiding - Pagina 30

Blader online of download pdf Installatiehandleiding voor {categorie_naam} HP ProCurve 1600M. HP ProCurve 1600M 46 pagina's. Redundant power supply
Ook voor HP ProCurve 1600M: Specificatieblad (12 pagina's), Lees mij eerst (8 pagina's), Handleiding voor recensenten (27 pagina's), Aanvullende handleiding (2 pagina's), Aanvullende handleiding (2 pagina's), Installatiehandleiding (28 pagina's), Installatiehandleiding (36 pagina's), Installatiehandleiding (28 pagina's), Handleiding voor snelle installatie (2 pagina's), Handleiding voor snelle installatie (4 pagina's), Gebruikershandleiding (8 pagina's), Handmatig supplement (28 pagina's), Lees mij eerst (16 pagina's), Installatie en verwijdering (2 pagina's), Installatiehandleiding (12 pagina's), Handleiding voor planning en implementatie (40 pagina's), Instructies voor demontage aan het einde van de levensduur van het product (2 pagina's), Diagnostische handleiding (2 pagina's), Demontage-instructies (2 pagina's)

HP ProCurve 1600M Installatiehandleiding
CAUTION
Connecting the DC Power Supply

Troubleshooting

Troubleshooting
If the Power Status LED and the switch Fault LED are flashing, one of
the following is probably occurring:
• The power supply is not connected to an active DC power supply
• The power supply is not properly installed
• A fault condition has been detected on the power supply.
To determine which condition exists, perform the following procedures:
1. Verify the power cable is connected to an active DC power source and
to the power supply. Make sure these connections are tight.
2. Try unplugging the power cable and plugging it back in to the power
supply.
3. If the Power Status LED continues to flash, verify the DC power
source works.
4. If the previous steps do not solve the problem, try removing and
reinstalling the power supply.
Disconnect DC power from the power supply BEFORE installing or
removing the supply. Not disconnecting the power first can damage the
power supply or switch. Read this manual for proper handling
procedures.
To avoid power supply or switch damage, do not attempt to power-up the
power supply outside the switch chassis. The power supply requires a
load and other enabling signals to operate properly.
If the power source and power cable are operating and this condition
persists, the switch power supply may be faulty.
30