2.
For any containers hosted on the failed GL node, issue cryptocfg --replace to
change the WWN association of containers from the failed GL node to the new GL node.
Replace the failed GL node with a new node:
1.
On the new node, follow the switch/node initialization steps.
2.
Create an Encryption Group on this fresh switch/node with the same Encryption Group
name as before.
3.
Perform a configdownload to the new GL node of a previously uploaded configuration
file for the EG from an old GL Node.
4.
For any containers hosted on the failed GL node, issue cryptocfg --replace to
change the WWN association of containers from failed GL node to the new GL node.
Initial setup of encrypted LUNs
IMPORTANT:
While performing first-time encryption to a LUN with more than one initiator active at the time, re-key
operations slow to a standstill. Define LUNs for a single initiator at a time to avoid this occurrence.
Fabric OS 6.2.0 fixes
The following table lists defects closed in the Fabric OS 6.2.0 firmware release.
Table 8 Fabric OS 6.2.0 closed defects
Closed defect summary
Add Member button is disabled while creating a new TI Zone when
the switch is in VF mode.
Under stress testing, cfgsave takes a long time and fails to propagate
on 64 VE-VE FCIP tunnel 33 switch core-edge topology running I/O.
Adding a B-Series switch with conflicting domain ID into an EOS fabric
may cause another switch to segment.
USB port LED of HP StorageWorks DC SAN Backbone Director CP
blade stays ON after HA failover.
CUP Port stuck in Contingent Allegiance State after z9 Host IPL.
Spinfab and porttest (diagnostics) are not supported on ICL ports.
Solution
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Add Other Port button can be used to
add ports.Tthis is available in the
ADD TI Zone window.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Wait until fabric is not saturated to
push configs around.
Fixed in Fabric OS 6.2.0.
Workaround prior to upgrade:
Check the domain ID before adding
a switch to any fabric.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
Fixed in Fabric OS 6.2.0.
HP StorageWorks Fabric OS 6.2.0b release notes
29