Ook voor HP XP20000/XP24000: Release Release (13 pagina's), Integratiehandboek (29 pagina's), Release Release (4 pagina's), Configuratiehandleiding (42 pagina's), Configuratiehandleiding (40 pagina's), Configuratiehandleiding (40 pagina's), Configuratiehandleiding (36 pagina's), Configuratiehandleiding (36 pagina's), Configuratiehandleiding (30 pagina's), Configuratiehandleiding (36 pagina's), Release Release (5 pagina's), Configuratiehandleiding (46 pagina's), Configuratiehandleiding (46 pagina's), Referentiehandleiding (46 pagina's), Configuratiehandleiding (40 pagina's), Configuratiehandleiding (44 pagina's), Configuratiehandleiding (38 pagina's), Configuratiehandleiding (34 pagina's), Configuratiehandleiding (30 pagina's), Configuratiehandleiding (30 pagina's)

HP XP20000/XP24000 Handleiding voor beheerders
[XP Virtualization Adapter][Time]: [failover_chk] : " Command line" ? P/S =
=
.
Cause - The pair status of a target volume specified with failover is inappropriate status (SMPL,
PVOL, or COPY).
Action to be taken - Confirm if volume status is appropriate status (XP Continuous Access is SVOL
and PAIR) using the pairdisplay command.
[XP Virtualization Adapter][Time]: [failover_chk] : The output of "Command line" is missing.
Cause - Could not find the correct format in the output of Command line command via failover.
Action to be taken - Confirm if XP RAID Manager is a version supported by XP Virtualization Ad-
apter.
[XP Virtualization Adapter][Time]: [testFailover_chk] : " Command line" ? P/S =
CTG =
.
Cause - The pair status of a target volume specified with failover testing is inappropriate status
(SMPL, PVOL, or NOT PAIR).
Action to be taken - Confirm if volume status is in the appropriate status using the pairdisplay
command (for XP Business Copy, SVOL and PAIR).
[XP Virtualization Adapter][Time]: [testfailover_chk] : The output of "Command line" is missing.
Cause - Could not find the correct format in the output of Command line command via failover
testing.
Action to be taken - Confirm if XP RAID Manager is a version supported by XP Virtualization Ad-
apter.
[XP Virtualization Adapter][Time]: [failover_exe] : invalid arrayId (- ).
Cause - A XML failover parameter was received from SRM to the XP Virtualization Adapter, but
the array ID could not be found.
Action to be taken - Use the SRM log message file to confirm the array ID parameter and XML
failover parameter.
[XP Virtualization Adapter][Time]: [testfailover_exe] : invalid arrayId (- ).
Cause - A XML failover testing parameter was received from SRM to the XP Virtualization Adapter,
but the array ID could not be found.
Action to be taken - Use the SRM log message file to confirm the array ID parameter and XML
failover testing parameter.

Troubleshooting information for technical support

Before calling technical support, collect the following information.
For SRM and XP Virtualization Adapter local configuration.
On Windows where SRM is running, execute the following procedures.
XP Virtualization Adapter local configuration
Collect the SRM log file on Windows on both protection and recovery site.
Collect the following SRM log file including the error messages of XP Virtualization Adapter
and SRM ERROR messages and XP RAID Manager command error log:
%ALLUSERSPROFILE%\ Application Data\VMware\VMware Site Recovery Man-
ager\Logs\vmware*.log
Collect the Outputs of the following command on HORCMINST=XX (instance# for XP Virtualiz-
ation Adapter)
42
Troubleshooting HP StorageWorks XP Virtualization Adapter
, Status =
, Fence
, Status =
,