aQuatell Fleck 5600SXT Gebruiksaanwijzing - Pagina 13
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} aQuatell Fleck 5600SXT. aQuatell Fleck 5600SXT 15 pagina's.
6. There should now be "VT" displayed in the top left of the screen. Press the UP button until
"St1B" appears in the center of the screen (please note that this may look like "St16"). Press
the EXTRA CYCLE button.
7. There should now be "CT" displayed in the top left of the screen. Press the UP button until
"Fd" appears in the center of the screen. Press the EXTRA CYCLE button.
8. There should now be "NT" displayed in the top left of the screen. Press the UP button until
"1" appears in the center of the screen. Press the EXTRA CYCLE button.
9. There should now be "C" displayed in the top left of the screen. Use the UP and DOWN
buttons to set the capacity of the softener. Use the following chart to match the softener you
purchased to the number you should enter for this step (use
suggested otherwise):
Softener Type
24,000 Grain (3/4 cubic foot)
32,000 Grain (1 cubic foot)
48,000 Grain (1.5 cubic foot)
64,000 Grain (2 cubic foot)
80,000 Grain (2.5 cubic foot)
96,000 Grain (3 cubic foot)
10. Once the proper number is displayed on the screen press the EXTRA CYCLE button.
11. There should now be an "H" displayed in the top left of the screen. Use the UP or DOWN
buttons to enter your water hardness value in Grains per Gallon. Add three grains per gallon
of hardness to this value for every 1.0 parts per million (ppm) of iron that is in your water.
Press EXTRA CYCLE.
12. There should now be "RS" displayed in the top left of the screen. Use the UP button to select
"SF" and then press the EXTRA CYCLE button.
13. There should now be "SF" displayed in the top left of the screen. Use the UP or DOWN
buttons to set the number to 15, and then press EXTRA CYCLE.
14. There should now be "DO" displayed in the top left of the screen. If you are using municipal
water source set this value to 14. If you are using any other water source set this value to 7.
Then press EXTRA CYCLE.
Value to use for
Salt
Efficiency
Method
15
20
30
40
50
60
Page 13
Fleck 5600SXT U.S. V1.1
Copyright aQuatell Inc 2010
Salt Efficiency
settings unless
Value to use for
Capacity
Method
24
32
48
64
80
96
Max