Replacement

Replacing the Auto Cleaning Filter (ACF)

 Before replacing the ACF
 Wait until the cooling fan stops and t
 Disconnect the mains lead from the mains socket.
 Contact an Authorised Service Centre to purchase a replacement ACF (ET-ACF100).
 The ACF unit to be replaced should be an unused product.
 When to replace the ACF
The ACF unit is consumable product and effects on ventilation. The FILTER indicator will inform you of the
replacement timing. You can check the remaining amount of the ACF unit in REMAINING FILTER of STATUS
in PROJECTOR SETUP menu.
 Replacement procedure
1. Loosen "ACF cover fixing screw" (1 screw) until the
screws turn freely and remove the ACF cover.
ACF cover fixing screw
ACF cover
2. Slide out the ACF unit from the projector slowly.
 When you replace the ACF unit, clean the
compartment and/or the air exhaust port if you need
to.
3. Insert the new ACF unit into the compartment in
correct direction and slightly push until it clicks.
ACF unit
E
NGLISH - 32
urn off the
switch of the projector in proper way.
POWER
4. Attach the ACF cover and tighten "ACF cover
fixing screw" (1 screw) securely.
NOTE:
• If the ACF and/or ACF cover are attached incorrectly, the
projector may not be turned on.
• The replacement timing of the ACF depends on environment of
usage.
 Resetting the REMAINING
FILTER
1. Turn on the projector and display the FILTER
COUNTER RESET in PROJECTOR SETUP
menu.
2. Press the ENTER button.
 The confirmation screen will be displayed.
3. Select OK by pressing I, then press the ENTER
button.
4. Display the STATUS in PROJECTOR SETUP
menu and confirm the REMAINING FILTER.