Panasonic PT-FX400U Spec Bestand - Pagina 13
Blader online of download pdf Spec Bestand voor {categorie_naam} Panasonic PT-FX400U. Panasonic PT-FX400U 15 pagina's. Pt-fw430 series
Ook voor Panasonic PT-FX400U: Brochure (2 pagina's), Gebruiksaanwijzing (46 pagina's), Specificaties (6 pagina's)
S
F
P
E
C
I
L
LCD Projector
Parameter format
Parameter format
Size (Byte)
<pl>
3 (1 or 2 bytes also
possible when
under control)
<off on>
1
<input signal>
3
<power condition>
3
<lamp condition>
1
<acctch>
4
<color temp>
1
<date>
8
<time>
6
NOTE: If a wrong command is received, the projector will send an ER401 command to the computer.
Command example
To set the volume to +30, send the command as shown below.
STX
Start
NOTE: When sending commands without parameters, a colon (:) is not necessary.
As of March 2011
SFL11M005-1
E
Definition
Decimal without signs: 0 –999 (000, 001, 002...999)
Decimal with signs: -99 to +99 (-99...-01, +00, +01, +02...+99)
Callback from the projector is 3 Byte.
0 = off, 1 = on
HD1 = HDMI, DVI = DVI-I, RG1 = computer,
NWP = network, VID = video, SVD = S-Video
000 = power off (standby mode off), 001 = power on (standby mode on)
0 = standby, 1 = lamp on under control, 2 = lamp off,
3 = lamp off under control
Dicimal without signs: 0000-9999 hours
0 = low, 1 = default, 2 = high
y1y2y3y4m1m2d1d2w = year (y) month (m) day (d) day of week (w)
Day of week: Monday = 1, Tuesday = 2, ... Sunday = 7
h1h2m1m2s1s2 = hour (h) minute (m) second (s)
AVL
:
30
Command
Parameter
ETX
End
PT-FW430
1 3 / 1 4