CONTROL PANEL & FLOATS
All electrical work shall be properly performed by a qualified electrician per all applicable codes. Always
have all utility lines and equipment marked by a locating service prior to performing any work. Failure to do
so may result in severe bodily injury or death.
The BioBarrier control panel, and all electrical parts supplied with the BioBarrier® system are ETL (UL equivalent) certified for
electrical safety. The control panel meets NEMA4X standards for all weather use (not explosive or submerged environments).
SECURING THE SYSTEM
29. Mount the 3 supplied channel strut pieces and associated hardware in the manhole so that the ¾" bracing pipes (from
steps 7 & 9) can be secured to the strut channel. Mount the strut end pieces to the tank riser using the supplied stainless
steel anchor bolts or other corrosion proof hardware.
30. Use "C" shaped brackets to fasten the ¾" bracing pipes to the strut channel so that the the BioBarrier system is held in
place in the tank.
31. Backfill the tank per professional judgment/requirements.
23. Install the floats on a pipe within 24" [61] of a BioBarrier membrane
module. DO NOT attach the floats to the aeration piping. Attach the
and YELLOW floats to the float tree at the locations shown. The
switch uses ONLY the brown and black wires. The YELLOW FLOAT switch
MUST be installed no higher than 2 inches [5 cm] BELOW the tank's inlet.
24. In the treatment tank, make connections to facilitate exiting of the
wiring from the discharge pump and the float switches. If a junction box is
used inside the treatment tank manhole, waterproof connectors must be
used.
25. Run these wires to the control panel. The float wires MUST be run in
separate conduit from any power wires.
26. Mount the BioBarrier control panel in a location that is accesible to a
service person, meets all code requirements and prevents voltage drop.
The 110VAC panel requires a 30A breaker minimum. The 220VAC control
requires a 20A breaker minimum.
27. Make connections inside the control panel as shown in the diagrams
included with the panel (and at the end of this manual). Note that ONLY
BROWN
and BLACK wires on the
the
the control panel.
BLUE
BLUE
float are to be connected to
BLUE
float