COM 1
COM 2
COM 3
SPECIAL PURPOSE
ALARM SYSTEM
ETC.
KEY-SWITCH OR
SOME SORT OF
SECURED SWITCH
( N.C. )
LOAD DRIVING
OUTPUTS CONFIGURED:
ALARM ACTIVATION
FOLLOWER MODE
Figure 3a—Normally Closed Switch
1
2
N.C.
1
COM.
N.O.
N.C.
2
COM.
N.O.
N.C.
3
COM.
N.O.
N.C.
4
COM.
N.O.
Figure 3c—Corridor Lights
Page 2 • IL882 NC050ES Remote LCD Receiver Manual
Figure 2—Inside the NC505ES
B
C
I
H
A
COM 4
COM 5
Figure 3—Wiring Examples
13
15
- OR -
AND
16
14
N.C.
COM.
N.O.
N.C.
COM.
N.O.
N.C.
COM.
N.O.
N.C.
COM.
N.O.
DOME LAMPS
4
3
BUZZERS
DOOR RELEASES
ETC.
OUTPUTS CONFIGURED:
ALARM ACTIVATION
FOLLOWER MODE
A
F
D
E
G
A
COM 6
SPECIAL PURPOSE
1
ALARM SYSTEM
2
PUSHBUTTON
( N.O. )
3
DRY CONTACT
4
OUTPUTS CONFIGURED:
ALARM ACTIVATION
FOLLOWER MODE
N.C.
1
COM.
N.O.
N.C.
2
COM.
N.O.
A - HOUSING RELEASE TAB
B - POWER
C - GND
D - POWER LOSS OUTPUT
E - RESET INPUT
F - TAMPER OUTPUT
G - JAM OUTPUT
H - OUTPUT TERMINALS
I - FREQUENCY SELECT
POWER
NC
COM
NO
PANIC,
5 OR 6
ETC.
Figure 3b—Normally Open Switch
6
DIALER
5
ALARM SYSTEM
OUTPUTS CONFIGURED:
ALARM ACTIVATION
SET MODE PER DIALER
Figure 3d—Output to Dialer
Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.
GND
N.C.
1
COM.
N.O.
N.C.
2
COM.
N.O.