Typical Low Pressure Propane Locker

Leak Test:

1. Do not use or permit sources of ignition in the area while doing the
leak test. This includes smoking.
2. Leak testing solution should be half liquid soap and half water.
3. Apply the solution to the LP gas delivery system at all connections.
4. Bubbles in the soap solution indicate that a leak is present.
5. The leak(s) must be stopped by tightening the loose joints, or
replacing the faulty parts.
***DO NOT USE BARBEQUE UNTIL LEAK IS CORRECTED***