Dickson TK856 Aan de slag - Pagina 3

Blader online of download pdf Aan de slag voor {categorie_naam} Dickson TK856. Dickson TK856 8 pagina's. Remote sensing temperature recorder

1. 1. 1. 1. To set the alarm, make sure unit is on and press and hold the Alarm
rapidly for about five seconds, then the LED will turn solid green. Release the Alarm
LED will turn solid red. At this point the display will show "On" or "Off".
Pressing either the Adjust
Adjust
Adjust
Adjust- - - - Up
switch, will toggle the alarm on or off.
2. 2. 2. 2. Pressing PEN
PEN
PEN
PEN HOME
HOME will scroll to the next alarm options.
HOME
HOME
Pen 1 alarm minimum
Pen 1 alarm maximum
If KT856 two pen model, the additional options are:
Pen 2 alarm minimum
Pen 2 alarm maximum
3. 3. 3. 3. In order to set pen(s) alarm minimums and maximums, pressing Adjust
value, and pressing Adjust
button is held down.
Repetitively pressing the Pen
is pressed to exit from alarm adjust. Each press of the Pe
settings. The unit will take one minute to exit Alarm Set Mode once the Alarm
4. 4. 4. 4. If the alarm is triggered, the LED will show as solid red and the alarm will sound. Press the Alarm
button to silence the audible alarm.
Alarm Relays
Alarm
Relays
Alarm
Alarm
Relays
Relays
The SPST 24V 500mA relay contacts are Normally open and will close on alarm conditions when the
alarms are enabled. Relay contacts are always functional when the alarm is enabled. The relay will close
only during minimum and maximum alarm conditions. The KT856 has 2 sets of relay contacts which
operate independently. Relays will not operate under battery only power conditions.
PENS
PENS
PENS
PENS
The blue pen has a longer pen arm and records channel 2 temperature (depending on your dip switch
selection, see pg. 4). The red pen has a shorter arm and records channel 1 temperature. The pens are
offset to allow the red pen to glide under the blue pen. The blue pen indicates the correct time and the
red pen precedes it by 3/16 of an inch.
Dickson KT8P Manual V6 52418
Up or Adjust
Up
Up
Adjust
Adjust- - - - Down
Adjust
Down
Down
Down buttons, located on the back of the unit next to the dip
Adjust- - - - Dow
Down n n n will decrease the alarm value. There is acceleration if the Adjust
Adjust
Adjust
Dow
Dow
Pen Home
Home button will scroll through the five options until the A A A A larm
Pen
Pen
Home
Home
Alarm button. The LED will blink red
Alarm
Alarm
Adjust
Adjust
Adjust- - - - Up
Up will increase the alarm
Up
Up
Pen n n n Home
Home or Alarm
Alarm button will store the new
Pe
Pe
Home
Home
Alarm
Alarm
Alarm
Alarm
Alarm button is pressed.
3
Alarm button and the
Alarm
Alarm
Adjust- - - - Up
Up
Adjust
Adjust
Up
Up
larm button
larm
larm
Alarm
Alarm
Alarm