FMSFLP
INITIALIZE MEDIA
Same as the format option described above, except that it doesn't format the media before writing the
logical drive information.
If the diskette's formatting is OK, use this option instead of format. This will save you
time.
If you initialize a diskette using a density that differs from its formatted density, the
diskette will be unusable.
MODE SENSE
Retrieves mode sense information from the drive. You can view these values:
• Current Values: control the current operation of the drive.
• Changeable Values: indicate which bytes/bits are changeable.
• Saved Values: control the current operation of the drive, unless they are changed by a
Mode Selected command.
• Default Values: used by the drive if current values have not been set or the drive is
unable to access its saved values.
The information you requested is displayed within a scrollable window. Use
information. Press
ESC
ERROR MESSAGES
?Logical format exceeds usable drive capacity!
You specified a logical drive count and bitmap size that exceeds the capacity of the
drive. Specify a smaller number of logical drives and/or bitmap size.
?Program requires AMOS/32 execution!
FMSFLP requires an MC68020 or later processor. It will not run on a computer with an
MC68000 or MC68010 processor.
?You must install a SCSI dispatcher to use FMSFLP on the system!
You are trying to run FMSFLP on a system that has a SCSI interface but does not have a
dispatcher installed.
?Device error id 5 - sense key: 03 (media error) additional sense: 12h 00h!
Ignore this error message.
when you are done.