Epever IPower IP1500-12 Gebruikershandleiding - Pagina 14

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Epever IPower IP1500-12. Epever IPower IP1500-12 20 pagina's. Pure sine wave inverter

Epever IPower IP1500-12 Gebruikershandleiding
protection
Rated power P
and recover
①When appear output overload protection or load short circuit protection, it has three times auto-recover
output function (The first time delay 5s, the second time delay 10s and the third times delay 15s).
e
S>2P
e
Load short circuit protection
S=1.5P
e
S=1.8P
e
(Rated input voltage)
11
Red indicator slowly flashing
Buzzer sounds
Output is OFF after 1min
Red indicator slowly flashing
Buzzer sounds
Output is OFF after 10s
Red indicator slowly flashing
Buzzer sounds
Output is OFF after 5s
Red indicator slowly flashing
Buzzer sounds
Output is OFF immediately
Red indicator fast flashing
Buzzer sounds