Olympus WINDER OM-1 Handmatig - Pagina 11

Blader online of download pdf Handmatig voor {categorie_naam} Olympus WINDER OM-1. Olympus WINDER OM-1 49 pagina's.
Ook voor Olympus WINDER OM-1: Gebruiksaanwijzing (16 pagina's)

Olympus WINDER OM-1 Handmatig
п.
Major Check
Relative Function
to be checked —
Checking Method or
Points
of Speciat Attention
"Воші
(1) Mirror
1)
movement
(2) Mirror
1)
position
2)
Upon shutter release, the mirror
should be raised accurately, and after
shutter opening and closure, it should
be lowered.
The mirror should make a smooth
operation (without hesitation and
unusual sound).
When the mirror is raised by the
MU knob, the edge of the mirror
should be in contact with the
damper and press it.
Upon shutter release by В or at
any slow speed, the mirror should
be completely out of the picture
frame during exposure but stay at
the upper edge of the frame.
FX Knob
(CA8896)
1.
Self-timer
р
2)
It should be properly set and stay
in such a position until released.
Setting should be performed without
heavy frictions, extreme uneven
feeling or squeaks, but smoothly.
Upon setting of the self-timer, the
setting lever alone will retum to
its original position smoothly with
proper friction but without staggering|
by self-weight.