4.
Use a spanner to close the shut-off valves of the
heat source (behind the covers).
5.
heat source.
Unit with
without cooling:
Unit with
Subject to change without notice | 83056700dUK – Translation into English of the original German operating manual | ait-deutschland GmbH
6.
Disconnect the electrical connections:
Unit up to 12 kW capacity:
– Disconnect 2 white connectors (1) at the
bottom of the electrical control cabinet. To
do this, release the lugs by pressing on the
sides of the connectors.
at the top of the module box.
1
Unit with 14 kW capacity and higher:
– Disconnect connector (1) at the bottom of the
electrical control cabinet.
– Disconnect connector (2) at the bottom of
the electrical control cabinet. To do this,
remove the control cabinet cover and undo
the connector from the inside.
at the top of the module box.
1
2
2
3
13