Alpha-Med Alpha-Stim PPM Gebruikershandleiding - Pagina 9

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Alpha-Med Alpha-Stim PPM. Alpha-Med Alpha-Stim PPM 11 pagina's. Personal pain manager microcurrent stimulator for control of acute, chronic, and post operative pain

Precautions:
For external use only. Do not allow children to use or handle this device without adult supervision. Do
not operate potentially dangerous machinery or vehicles during, and in some cases, for several hours after treatment.
Caution is advised in cases where other forms of analgesia (pain control) would not be used; such as to retain the
beneficial aspects of pain for diagnosis or in cases where people may overuse pain-controlled areas. Safety of
stimulation has not been established during pregnancy.
Adverse Effects:
Adverse effects are usually mild and self-limiting. Adverse effects from approximately 4,541
patients participating in controlled, open, uncontrolled research, and by physician survey are skin irritation/electrode
burns (5 cases, 0.11%), and headaches (9 cases, 0.20%).
If the Alpha-Stim® PPM does not control your pain within 3 weeks, consult your physician.

TECHNICAL SPECIFICATIONS

Electrical
Power Source
Two AAA 1.5 volt batteries (included). Replace with disposable batteries (alkaline preferred).
Do not use rechargeable batteries.
Timer
Continuous
Current
10 to 600 µA continuously adjustable
Frequency
0.5 Hz (pulses per second)
Waveform
Bipolar asymmetric rectangular waves, 50% duty cycle, 0 net current (see graphic depiction)
Mechanical
Height
8.0 cm
Width
5.8 cm
Depth
2.0 cm
Weight
82 gm with battery
Accessories
The Alpha-Stim® PPM is packaged complete with one set of 4 self-adhesive AS-Trode™ brand silver electrodes
(good for
approximately 2 weeks to 1 month of use), electrode wires, two 1.5 volt AAA batteries, and an illustrated Owner's
Manual. This is everything necessary to begin to use the Alpha-Stim® PPM right away. Replace self-adhesive
electrodes only with authorized Alpha-Stim® and AS-Trode™ brand products.

STORAGE AND CLEANING

Remove the batteries when storing the Alpha-Stim® PPM for an extended time (more than 1 month). The Alpha-
Stim® PPM and all its accessories should be stored and used within a temperature range between 0° and 36° C, with
a relative humidity of 90% or less, at an atmospheric pressure between 0.9 - 1.1 atm. Clean the Alpha-Stim® PPM by
periodically gently wiping the surface with a damp cloth when dirty. Use mild soap and water. Use of other cleaning
solutions may damage the case. Never spray cleaners directly on to the device.