The measured capacities can be, as well as in the "Charge Test", retrieved by pressing the
channel button. If a high charging current is chosen, it can happen in some cases that the
full charging capacity is not reached (this depends on the quality and condition of the
battery).
A lower charging current is able to put more energy into the battery but therefore the
procedure lasts longer. The procedure to see the chosen currents and the measured
capacities is the same as for "Charge Test". This is the best way to measure the current
state of health of the battery (still available capacity of the cell).
At "Charge Test" and "Discharge Test" the discharging current will be selected
automatically to 500 mAh. The table below shows the selectable charging current values
followed by its discharging current.
Selected charging current
Following discharge current
Charge:
If you like to charge one or more batteries, it distinguishes between same type or different
cells:
• Batteries of the same type
Firstly, insert the batteries into the charger. The charger registers the inserted
batteries and starts to identify the battery chemistry. By default, the charge process
and a charging current of 500 mA gets selected automatically. The same conditions
will be used for all inserted batteries and can be changed through pressing the
mode button. If you want to change the settings, you can do that as long as the font
is flashing. The desired program can be selected by pressing the MODE button as
well as the charging current can be selected with the CURRENT button. After the
font stops flashing, the program is activated and starts to charge/discharge the
batteries.
TIP: Disconnect the charger from the power, insert the batteries in the channels,
connect the charger to the power again and select the wanted conditions through
the LC Display flashes, as mentioned above.
• Individual setting:
If you want to charge different batteries with individual settings, it is recommended
to insert the batteries separately one by one. Only when all the settings via the
appropriate keys were selected for the first battery and the font on the LC display
stops flashing, the battery is taken from the charger. Now the next battery can be
inserted and selected as described before. If you like to change the selected
program, press the mode button for some seconds till the font starts to flash on the
LC display and then it is possible to change the function through pressing the mode
button again. If you like to change the current you can change it through pressing
the CURRENT button, that's possible as long as the function flashes on the LC
display, after some seconds the charger accepts the now selected information and
stops flashing.
If the charger started the selected program, it can only be interrupted through removing the
cells from the slots or pressing the mode button for some seconds. Short pressing of the
mode button cannot interrupt the running program. This is a protection against
unintentional cancel the program.
User Manual
300 mA
500 mA
300 mA
300 mA
5/7
700 mA
1000 mA
500 mA
500 mA
Update version-V2