Axor Shower Select Square 36718007 Gebruiksaanwijzing/montagehandleiding - Pagina 4
Blader online of download pdf Gebruiksaanwijzing/montagehandleiding voor {categorie_naam} Axor Shower Select Square 36718007. Axor Shower Select Square 36718007 20 pagina's.
EN
0 4
S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Children as well as adults with physical, mental and ⁄or
sensoric impairments must not use this product without
proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
⁄ This mixer cannot be used in conjunction with
hydraulically, electronically or thermally controlled
instantaneous heaters.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 08)
After the installation, the output temperature of
the thermostat must be checked. A correction is
necessary if the temperature measured at the
output differs from the temperature set on the
thermostat.
S A F E T Y F U N C T I O N (see page 08)
The desired maximum temperature for example
max. 42º C can be pre-set thanks to the safety
function.
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C ⁄ 4 min
M A I N T E N A N C E (see page 10)
⁄ The check valves must be checked regularly
according to EN 806-5 in accordance with
national or regional regulations (at least once
a year).
⁄ To guarantee the smooth running of the
thermostat, it is necessary from time to time to
turn the thermostat from total hot to total cold.
D I M E N S I O N S (see page 17)
F L O W D I A G R A M (see page 17)
f ree flow
C L E A N I N G (see page 12)
S P A R E P A R T S (see page 14)
+
S P E C I A L A C C E S S O R I E S
(see page 16)
o rder as an extra
⁄ extension 25 mm #13595000
⁄ Extension Set 22 mm (when wall is not deep
enough) #98860000, #97407000,
13596000
⁄ Extension Set 33 mm (when wall is not deep
enough) #14971000, #14964000,
14960000
O P E R A T I O N (see page 17)