Front-Panel Components
•
Fuse: should a short circuit occur, the fuse will burn out protecting the pump and
cooling fan�
•
Power Switch: Provides power to the unit�
•
Water Outlet Joint: Connected by a water line to the water inlet joint�
•
Return Water Joint: Connects to the return water line�
•
Buzzer: Any bloackage of return water supply will sound this alarm�
Machine Operation
Check the water level by looking through the water window� The water level needs to be
greater than half the rated capacity of the water tank. Confirm the connection of the inlet
and return water joints� Turn on the power supply�
Caution
•
When environment temperature is greater than 105 °F, tap water or other neutral
water with a PH of 7 can be used�
•
When environment temperature is less than 105 °F, ionized water, cooling fluid,
antifreeze, or a 1/3 alcohol 2/3 distilled water should be used� Freezing water will
burst and damage the pump�
•
Do not exceed the rated capacity of the water tank�
•
While in use, make sure the water tank is greater than half-full� Water should be
added as needed�
•
When environment temperature is below than 105 °F, drain the water from the
system to avoid freezing�
•
If the unit will not be used for a long period of time, water should be drained from
the system�
(Note: there is a small amount of water stored in the condenser. Use compressed air on
the return water joint to blow water into the tank.)