Connections
Worksurface Rear Panel ...............................................................
Function Connector Comments
MADI Audio I/O Female BNC 2 Pairs of I/O (arranged as 2 redundant pairs - 4 sockets)
Optocore HMA 2 Bidrectional dual connector (optional)
Analogue Mic/Line Inputs 8 x XLR female 8 Channels per card, electronic balanced, Pin 2 Hot
Analogue Line Output 8 x XLR male 8 channels per card, electronic balanced, Pin 2 Hot
AES/EBU Input / Output 8x XLR 4 Female (input) + 4 Male (Output) floating balanced
MIDI In/Out/Thru 5 pin DIN MMC, MTC
AES/EBU Input Female XLR Sync input ONLY
AES/EBU Output Male XLR Null signal sync output ONLY
Word Clock Input BNC External clock input
Word Clock Output BNC Clock output follows console (5Vp-p)
External Monitors 15 pin HD D Overview, adjustable resolution
Ideally use 1280 x 1024 SVGA
Network RJ45 Ethernet compatible (Not implemented for general use)
USB x 2 A type sockets
Keyboard PS2 mini DIN
Mouse/trackball PS2 mini DIN
Mains Power IEC power x 2 Dual redundant supplies
90V-260V 50-60Hz auto sense
With the dual redundant PSUs, the console requires 2 separate mains connections. It will operate on only 1 supply.
Supply units can be switched off, removed and replaced whilst the other is use (hot swappable)
Worksurface Front Panel ..............................................................
USB A type
Headphones 1/4" (6.3mm) stereo jack
I/O Rack Control Panel .................................................................
Digirack Function Connector Comments
MADI I/O BNC socket 2 Pairs of I/O to Console
Optocore HMA 2 Bidrectional dual connector (optional - not MadiRack)
Word Clock Out BNC socket 48/44.1 KHz 5V p-p
Word Clock In BNC socket 48/44.1 KHz 5V p-p max
Mains Power IEC power x 2 Dual redundant supplies
Stage rack 175VA run
FOH rack 175VA run
90V-260V 50-60Hz auto sense
Requires 2 separate mains connections. Rack will operate on only 1 supply for short periods. Supply units on the DigiRack can be
switched off, removed and replaced whilst the other is use (hot swappable), not on MadiRack or MiniRack.
Madirack Function Connector Comments
MADI I/O BNC socket 2 Pairs of I/O to Console
Word Clock Out BNC socket 48/44.1 KHz 5V p-p
Word Clock In BNC socket 48/44.1 KHz 5V p-p max
Mains Power IEC power x 2 Dual redundant supplies
Stage rack 160VA run
90V-260V 50-60Hz auto sense
Requires 2 separate mains connections. Rack will operate on only 1 supply for short periods.
Minirack Function Connector Comments
MADI I/O BNC socket 2 Pairs of I/O to Console
Optocore HMA 2 Bidrectional dual connector (optional - not MadiRack)
Word Clock Out BNC socket 48/44.1 KHz 5V p-p
Word Clock In BNC socket 48/44.1 KHz 5V p-p max
Mains Power IEC power x 2 Dual redundant supplies
Local Mine rack 125VA run
90V-260V 50-60Hz auto sense
Requires 2 separate mains connections. Rack will operate on only 1 supply for short periods.
Page 11