Axxeron HESCH HE 5711 Gebruiksaanwijzing - Pagina 16

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Axxeron HESCH HE 5711. Axxeron HESCH HE 5711 19 pagina's. Solenoid valve controller

5.3

Connection diagram

Terminal
L (+)
N (-)
PE
+ START [Start]
- START [Start]
+ START CYCLE
- START CYCLE
+V1
-V1
+V2
-V2
+V3
-V3
+V4
-V4
+V5
-V5
+V6
-V6
+V7
-V7
+V8
-V8
16
Name plate
Connection diagram
Meaning
Supply voltage L, 100...240 V AC or (+) 24 V DC
Supply voltage L, 100...240 V AC or (-) 24 V DC
Protective earth
Input cleaning start (+), Active Low
Input cleaning start (GND)
Input cyclic cleaning (+), Active Low
Input cyclic cleaning (GND)
Output of valve 1 (+24 V DC)
Output of valve 1 (GND)
Output of valve 2 (+24 V DC)
Output of valve 2 (GND)
Output of valve 3 (+24 V DC)
Output of valve 3 (GND)
Output of valve 4 (+24 V DC)
Output of valve 4 (GND)
Output of valve 5 (+24 V DC)
Output of valve 5 (GND)
Output of valve 6 (+24 V DC)
Output of valve 6 (GND)
Output of valve 7 (+24 V DC)
Output of valve 7 (GND)
Output of valve 8 (+24 V DC)
Output of valve 8 (GND)
HE 5710 / 5711 Operating Instructions
# 371814 | Version 1.4