Mode 4: Latched outputs
Description: Allow the capability of making a pulsed signal a latched signal.
Connections:
Interface wiring
Pin 4 (Pink)
Pin 6 (Green)
Pin 7 (Red)
Pin 8 (Blue)
Pin 9 (Brown)
Pin 10 (Gray)
To
Ground
Negative latched output (500 mA max)
Negative latched output (500 mA max)
Positive latched output (2 amp max)
Positive pulsed input (use only one)
Negative pulsed input (use only one)