ABB PSTX142 170 Series Instructie reserveonderdelen - Pagina 5
Blader online of download pdf Instructie reserveonderdelen voor {categorie_naam} ABB PSTX142 170 Series. ABB PSTX142 170 Series 6 pagina's.
3. PSTX210...370
- Replace the current transformer
WARNING
Always make sure that the power supply is
switched off before doing maintenance on the
Softstarter.
1
1
2
4
7
2
Hex no. 8
M10x60
(12Nm)
1
10
2
Tx 15
M3,5x12
Tx 20
M4x12
5
Tx 30
M6x25
8
Tx 25
M5x18
(3Nm)
3
11
1SFC132106M0201
WARNING
When performing maintenance on the Softstarter,
an antistatic strap must be used. The antistatic
strap should be worn on the wrist, and be
connected to an electrical ground, to prevent
electrostatic discharge (ESD) damage to the
Softstarter.
3
6
2
Tx 15
Tx 30
M3,5x12
M6x25
9
Tx 25
M5x18
(0,5Nm)
Tx 30
M6x25
(8Nm)
12
| Spare part instruction - Replace the current transformer |
Hex no. 8
Tx 25
M10x60
M5x18
1
3
Tx 30
M6x25
(8Nm)
2
Tx 15
3
M3,5x12
(0,5 Nm)
Tx 20
M4x12
(1,6 Nm)
1
5