Technical Data

Connection data
Power cable cross section
Cable gland
Type of protection
Ambient operating temperature
Type of protection
Ambient operating temperature
Storage temperature
Operating utilization
Operating mode
Housing degree of protection
Insulation class
Overvoltage category
Sound pressure
Material
Name plate identification
FHF Funke+Huster Fernsig GmbH D-45478 Mülheim
PTB 07 ATEX 2039 X
IECEx PTB 10.0054 X
II 2 G Ex e mb IIC T5* Gb
Ex e mb II T5*
-20°C Ta +50°C* or
II 2 G Ex e mb IIC T5* Gb
Ex e mb II T5*
-20°C Ta +60°C* or
II 2 G Ex e mb IIC T4* Gb
Ex e mb II T4*
-20°C Ta +70°C*
Ui = *) ...... IP *)
Do not open while under power
CE
P/N: ...............
F-No.:..................
Clean with moist cloth only.
WARNING! – Potential electrostatic charging hazard – see instructions
*) acc. to version

Electrical characteristics

Connection data
6 VAC 50 Hz
12 VAC 50 Hz
24 VAC 50 Hz
60 VAC 50 Hz
115 VAC 50 Hz
230 VAC 50 Hz
120 VAC 60 Hz
240 VAC 60 Hz
4
up to 2.5 mm
M20 x 1.5
II 2 G Ex e mb IIC T5 Gb
Ex e mb II T5
DC versions
-20°C up to +60°C
II 2 G Ex e mb IIC T4 Gb
Ex e mb II T4
DC and AC versions
-20°C up to +70°C
-40°C up to +80°C
Sound outlet position downwards
Duty cycle DC 75%
IP54
II
II
ca. 108 dB(A), 1m
PC, black
+10/-15%
3.40 A
+10/-15%
1.20 A
+10/-15%
0.65 A
+10/-15%
0.25 A
+10/-15%
0.15 A
+6/-15%
0.07 A
+10/-15%
0.15 A
+10/-15%
0.07 A
2
AC versions
-20°C up to +50°C
Connection data
6 VDC
12 VDC
24 VDC
48 VDC
60 VDC
115 VDC
230 VDC
+10/-15%
1.00 A
+10/-15%
0.60 A
+10/-15%
0.30 A
+10/-15%
0.24 A
+10/-15%
0.15 A
+10/-15%
0.08 A
+10/-15%
0.05 A