VI. Display symbols
7
8
6
9
5
4
3
2
1
1.Low battery indicator;
2.Negative polarity indicator;
3.AC signal measurement indicator;
4.DC signal measurement indicator;
5.Automatic range indicator;
6.Diode measurement indicator;
7.Continuous inspection indicator;
8.Maximum measurement indicator;
9.Data hold indicator ;
10.Relative value measurement indicator;
11.Triode measurement indicator;
12.Degree centigrade measurement indicator;
13.Fahrenheit measurement indicator;
14.Resistance measurement unit (Ω ohm, kΩ kiloohm, MΩ megohm);
15.Current measurement unit (A ampere, mA milliampere, uA microampere);
16.Voltage measurement unit (V volt, mV millivolt, uV microvolt).
Note: item 10, 11, 12 and 13 are not available for 6016A
VII. Key functions and auto power-off
SELECT:Press the button to select indicated measurement function when there are two or more
measurement functions on the same gear. It shifts between diode and buzzer measurements.
RANGE: The meter is in automatic range when starts up, press the "RANGE" button to activate
manual range mode. In the mode of manual range, each press lets the meter skip to the previous shift.
When it goes to the highest shift, it goes back to the lowest shift automatically. The procedure
repeats again in the same order. Press the "RANGE" button over 2 seconds, it will exit from manual
range measurement mode and shift to automatic range measurement mode.
HOLD:Press the "HOLD" button, the measurement value showed on the screen will be locked.
Press this button again, it will unlock and enter the state of regular measurement.
MAX : Press the "MAX" button, the display screen will show maximum value of the whole
measurement process automatically. Press this button again, it will cancel maximum reading hold
status and enter the state of regular measurement.
Auto power-off function: In measurement process, if function button or function/range selection
switch has no operation within 15 minutes, the meter will "power-off automatically". In the mode
of auto power-off, press function button (valid operation) or rotate function/range selection switch,
the meter will "power on automatically" and enter the measurement mode. Press and hold
"HOLD" button when start up, the auto power-off function will be canceled.
Note: "Auto power off" refers to a dormant state. In dormant mode, small current (about 5μA)
will be consumed. If it will not be used for a long time, please cut off power and take the battery out.
Buzzer: Press any one of functional buttons at any gear, if the button is effective, the buzzer will
beep. (2/20A buzzer will make no sound , and keep silence if the operation is invalid.) About 1