Cres Cor 1254-044 Gebruiks- en onderhoudsinstructies - Pagina 4
Blader online of download pdf Gebruiks- en onderhoudsinstructies voor {categorie_naam} Cres Cor 1254-044. Cres Cor 1254-044 4 pagina's. Hot cabinet
FL-1390-3
Hot Cabinet
Rev. 5 (3/10)
Page 4 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Models: 130B and 131B Series Hot Cabinets
52
50
51
FOR 220V
4
3
2
1
TRANSFORMER
110V/220V
8
5
DIP SWITCH (SW1)
SENSOR
SETTINGS
1
2
3
1 2
t°
OFF
OFF
F°
C°
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
GREEN
5-20P
120V, 20A
G
GREEN
6-15P
240V, 15A
G
50
51
50
FOR 120V
4
3
TRANSFORMER
110V/220V
8
SENSOR
3
t°
WIRE HARNESS 5812-918
OPTIONAL
5925 Heisley Road • Mentor, OH 44060-1833
G
W
G
BROWN
W
1
TERMINAL
BLOCK
3
50
51
51
1
2
1
4
3
5
SLEEVING
TERMINAL
BLOCK
BLUE
2
5
11
2
5
11
THERMOSTAT
ELECTRICAL SPECS.
Model 1254-044
2075W, 120V, 60 Hz, 1 Ph
AC Service
Model 1254-045
2075W, 240V, 60 Hz, 1 Ph
AC Service
HEATER
12
BLOWER
SPLICE
13
14
1
2
3
4
PILOT
POWER
LIGHT
SWITCH