ARCHPOT 304 Installatie- en bedieningshandleiding - Pagina 2

Blader online of download pdf Installatie- en bedieningshandleiding voor {categorie_naam} ARCHPOT 304. ARCHPOT 304 12 pagina's. Apf burner system

ARCHPOT 304 Installatie- en bedieningshandleiding
Gas
Requirements
Description
12" Round Duel Burner, 304 Stainless Steel
18" Round Duel Burner, 304 Stainless Steel
24" Round Duel Burner, 304 Stainless Steel
30" Round Triple Burner, 304 Stainless Steel Up to 175,000 3/4" Female NPT
Gas Pressure (Nominal)
Natural Gas
Propane
WARNING!
If you smell gas, immediately take the following actions:
1. Do not attempt to ignite your appliance.
2. Shut off the gas to the appliance.
3. Extinguish any open flame near the unit.
4. If odor lingers, call your gas supplier or local fire department.
• Do not store or use any gasoline or other flammable vapors and/or liquids in the
vicinity of this or any other appliance.
• Never attempt to burn wood or any other flammable materials in this fire feature.
Electrical
Requirements
WARNING!
The All Weather Electronic Ignition System operates on either 24 Volts AC or 30 Volts DC power ONLY
(Depending on which system you have. Check labeling to ensure which voltage is required)
DO NOT Attempt to Power using 110 Volts AC Power – Damage WILL RESULT
Recommended Wire Size: 12-gauge wire for all installations
Daisey Chain Wiring of Multiple AWEIS
BTU Rating
7" wc
11" wc
Gas Inlet Size
Up to 90,000
1/2" Female NPT
Up to 125,000 1/2" Female NPT
Up to 150,000 1/2" Female NPT
The AWEIS have a Yellow and a Blue wire protruding
from them. These are the power wires. When daisy
chaining multiple AWEIS the polarity between them
must be the same. To achieve this all the Yellow
wires must be connected to the same wire from the
transformer and all the Blue wires connected to the
other wire from the transformer as shown in this
illustration.
NO MORE THAN 2 AWEIS ARE TO BE
DAISY CHAINED TOGETHER
2