ArchWork ARCTAB Gebruikershandleiding - Pagina 15
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} ArchWork ARCTAB. ArchWork ARCTAB 20 pagina's. Touch-sensitive dmx interface
- 2 - INSTALLATION
2.1 MOUNTING
The ARCTAB controller can be installed in any standard electrical backbox. If you use a double size box, you
can insert the power supply inside.
• Mount the back side of the interface on the wall with 2 or more screws.
• Plug the 2 connectors (green connector block, fig.3).
• Close the interface, using one screw.
2.2 CONNECT THE WIRES
• DMX: Connect the DMX cable to the lighting receivers (Leds, Dimmers, Fixtures..)
(for XLR: 1=ground 2=dmx- 3=dmx+).
• Connect a 9V DC 0.65A. Be sure to not invert the + and the ground.
NOTE - PORT 1,2,3,4 : If your application need to have some external contact closures, make the contacts
between the ground and the ports.
Follow the wiring diagram as shown in figure.
ARCTAB
BLOCCO
CONNETTORI
DMX
XLR: 1 = Massa
2 = DMX-
3 = DMX +
POWER
Fig.3
5