Digimax 210 Gebruikershandleiding - Pagina 3
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Digimax 210. Digimax 210 12 pagina's. Programmable thermostat compatible with maxi controller
Ook voor Digimax 210: Gebruikershandleiding (11 pagina's)
To change the "Set Point" (i.e. temperature requested), press
and hold the "SET" key and at the same time press "+" or "-"
to select the temperature setting. The display will show the
"Set Point" until the "SET" button is released. The display will
then show the ambient temperature.
When the DigiMax 200 instructs your heating system to switch
on, a small flame symbol appears at the bottom right of the
display.
I
II. Installation :
DigiMax 210 Technical Data
Temperature Range :
5°C to 35°C in 1°C steps
16°C to 35°C selectable
Differential :
<1°C at 4K per Hour
Ambient temperature :
Operating 0°C to 45°C
Power Supply :
3 type AA 1.5 v alkaline cells
Switch :
230v ac 2 (1)A
Battery Life :
2 years Typical
Maintenance :
no user maintenance required
RF range :
30 meters
Please read all installation instructions before proceeding.
The RF DigiMax 210 works with batteries. It does not need
any wire. If you wish it to replace an old cable thermostat,
isolate and secure the old wires, which are useless now. Do
not forget to cut the power when you take off the old thermo-
stat.