Ook voor Cisco AJ732A - MDS 9134 Fabric Switch: Configuratiehandleiding (49 pagina's), Release Release (48 pagina's), Release Release (44 pagina's), Release Release (44 pagina's), Release Release (36 pagina's), Release Release (22 pagina's), Snelle referentiehandleiding (14 pagina's), Release Release (3 pagina's)

Cisco AJ732A -  MDS 9134 Fabric Switch Release Release
S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m
CSCsv70815
Symptom: The default VRF is the system default for a VRF setting. Ideally, applications using VRF
(such as TACACS+) assume a default VRF value if a VRF configuration is not specified by the
administrator. However, TACACS+ is not set up properly unless the default VRF is configured.
Workaround:
The Cisco Nexus 5000 Series switches support two possible VRFs, the default and the management.
Configure the desired VRF when using TACACS+ service. You can configure the desired VRF using
either of these configurations:
aaa group server tacacs+ t1
aaa group server tacacs+ t2
server 20.1.1.2
use-vrf default
CSCsu01188
Symptom: No traps are sent when SFPs for GE and 10GE are removed or inserted.
Workaround: None.
CSCsv56881
Symptom: Each Switched Virtual Interface (SVI) for inband management must be configured with
a different IP address. IPv6 has an error check feature. When an administrator enters a duplicate
IPv6 address across two SVIs, the software fails the command due to the duplicate address. A
similar error check should exist for IPv4 address configuration on SVIs.
Workaround: Do not configure duplicated IPv4 or IPv6 addresses.
CSCsv52513
Symptom: The VLAN interface 1 is internally created by the SVI daemon by default, so this VLAN
interface cannot be deleted from the CLI.
Workaround: None.
CSCsv24214
Symptom: When downgrading a Cisco Nexus 5000 Series switch from running a 4.0(1a)N1 image
to a 4.0(0)N1(1) or 4.0(0)N1(1a) image, the startup configuration is not restored. This is caused by
the defect CSCsq74395, which was resolved in 4.0(0)N1(2) and 4.0(0)N1(2a).
Workaround: After a downgrade, manually copy the startup configuration to the running
configuration and reboot the system.
CSCsv02866
Symptom: The command show interface ethernet transceiver details may show invalid
calibration for DOM-supported 1 G SFP.
Workaround: None.
CSCsv10783
Symptom: The show startup-config does not show the correct mode for a channel group. It shows
the current mode for the channel group. The correct mode is stored. On a subsequent reload, the
correct mode is configured on the channel group. The show startup-config always shows the current
mode instead of the mode that was saved to startup. On a subsequent reload, the correct mode is
configured. This is only a show command issue.
Workaround: None.