Digiscan Labs DNG-2300 Gebruikershandleiding - Pagina 10

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Digiscan Labs DNG-2300. Digiscan Labs DNG-2300 11 pagina's.

Digiscan Labs DNG-2300 Gebruikershandleiding
position.
4. Increase the output level until the LOOPBACK indicator shows the middle reading – the red light
should be on the 10
5. Place the DNG-MIC where a potential listening device could be hidden or a person carrying
a recorder or a microphone could stand/sit. Check that the LOOPBACK reading is not less
than 10. Increase the level if necessary. Probe all places where a person could stand or sit.
Repeat the tuning for spaces above the ceiling tiles, in closets/crawl spaces, ventilation channels,
etc.
VERIFICATION
When inspecting for acoustic leakage, a "Known Sound Source" such as a cassette or compact disc
player should be placed in the center of the target area. Set the volume to a normal level for
conversation in that area and leave the DNG-2300 off. Carefully probe any surface from the inside
or outside that is connected to the target area, including windows, doors, plumbing, air ducts, etc.
The identification of the KSS with the contact microphone will expose the existence of a possible
acoustic leak; these locations should be noted. Turn on the DNG-2300 and listen again for the KSS
to verify effective masking. The KSS should not be heard through the generated noise. Adjust levels
as required.

SPECIFICATIONS

Digital Noise Generator DNG-2300
Size
Weight
Output Max
Min. load channel
1,2
Min. load channel
3
Frequency
Power
Transducer TRN-2000
Size
Weight
Impedance
Omni Speaker OMS-2000
Size
Weight
Impedance
Probe microphone DNG-MIC
Output Level
Weight
th
segment of the bargraph.
1.7 x 5.9 x 10 in. (4.4 x 15 x 25.4 cm)
2.2 Kg
2 x 8W
3 ohms
8 ohms
250-5000 Hz
110 V 60 Hz (220V 50 Hz)
3 x 1.25 in. (7.6 x 3.1 cm)
1 lb (454 g)
6 ohms
5 x 5.75 in. (12.7 x 14.6 cm)
2 lb. (907 g)
24 ohms
1 V
110 grams
10