NOTE
Parameter 51 is active
only if parameter 50 is
not set to 0.
i
NOTE
Temperature
meas-
urement is performed
before sending any
report (regardless of
parameter no. 50). Ex-
cessive reporting can
affect battery lifetime.
Reporting on the ba-
sis
of
temperature
change
(parameter
no. 51) is recommend-
ed.
ADVAnCED PARAMETERS
15. Association for closing - time delay
Time that must elapse from closing to send the command frame to
devices in 2nd association group.
Available settings: 0-32400 - time in seconds
Default setting:
30. Tamper - alarm cancellation delay
Time period after which a tamper alarm will be cancelled.
Available settings: 0-32400 - time in seconds
Default setting:
31. Tamper - reporting alarm cancellation
Reporting cancellation of tamper alarm to the controller and 3rd as-
sociation group.
Available settings: 0 - do not send tamper cancellation report
Default setting:
50. Interval of temperature measurements
This parameter defines how often the temperature will be measured.
The shorter the time, the more frequently the temperature will be
measured, but the battery life will shorten.
Available settings: 0 - temperature measurements disabled
Default setting:
51. Temperature reports threshold
This parameter defines the change of temperature in comparison
with last reported, resulting in temperature report being sent to the
main controller.
Available settings: 0 - temperature reports based on threshold
Default setting:
52. Interval of temperature reports
This parameter determines how often the temperature reports will be
sent to the main controller (regardless of parameters 50 and 51).
Available settings: 0 - periodic temperature reports disabled
Default setting:
0
Parameter size:
5
Parameter size:
1 - send tamper cancellation report
1
Parameter size:
5-32400 - time in seconds
300 (5min)
Parameter size:
disabled
1-300 - temperature threshold (0.1-30°C, 0.1°C
step)
10 (1°C )
Parameter size:
300-32400 - time in seconds
0
Parameter size:
2 [bytes]
2 [bytes]
1 [byte]
2 [bytes]
2 [bytes]