Sharp 14BM2G Servicehandleiding - Pagina 9

Blader online of download pdf Servicehandleiding voor {categorie_naam} Sharp 14BM2G. Sharp 14BM2G 40 pagina's.

HORIZONTAL, VERTICAL, DEFLECTION LOOP AND FOCUS ADJUSTMENT
NO. Adjustment part
Adjusting procedure and conditions
1
V-SLOPE
1. Receive Monoscope Pattern Signal.
(I
2
C BUS
2. Call the "V-LIN" mode.
CONTROL)
3. Increase or decrease "V-LIN" by Volume key till
the horizontal line in the center of monoscope is
just at the position where the blanking starts.
2
V-SHIFT-50
1. Call the "V-CENT" mode.
(I
2
C BUS
2. Increase or decrease "V-CENT" by Volume key
CONTROL)
till the picture is centered.
3
V-AMP 50
1. Call the "V-AMP" mode.
(I
2
C BUS
2. Increase or decrease "V- AMP" by Volume key
CONTROL)
to set overscan of 9.5% typical.
Adjustment Spec 9.5% range +1% -0%.
4
S-CORRECTION
FIXED DATA, NO NEED TO ADJUST.
(I
2
C BUS
CONTROL)
5
H-SHIFT (50)
1. Call the "H-CENT" mode.
(H-CENTER)
2. Increase or decrease "H-CENT" by Volume key
(I
2
C BUS
to center the picture horizontal.
CONTROL)
1
FOCUS
1. Receive the "Monoscope Pattern" signal.
ADJUSTMENT
2. Press R/C to set Picture NORMAL condition.
3. Adjust the focus control to get the best focusing.
PAL CHROMA ADJUSTMENT
NO. Adjustment part
Adjusting procedure and conditions
1
SUB COLOUR
1. Receive the "PAL Colour Bar" signal.
(I
2
C BUS
2. Press R/C to set Picture Normal condition.
CONTROL)
3. Connect the oscilloscope to Red cathode.
» Range
: 20 V/Div. (AC) (Use 10:1 probe)
» Sweep time : 10 µsec/Div.
4. Using the R/C call "SUB COL" in SERVICE
mode. Adjust SUB COLOUR bus data, so that
the 75% White & Red portions of PAL Colour
Bar be at the same level shown as Fig. 8.
5. Clear the SERVICE mode.
Waveform and others
Waveform and others
Cy G
W Y 100%W
Mg R
75%
Fig. 8
9-1
NTSC CHROMA ADJUSTMENT
NO. Adjustment part
Adjusting procedure and conditions
1
SUB-TINT
1. Receive the "NTSC 3.58 Colour Bar" signal thru
(I
2
C BUS
AV in.
CONTROL)
2. Connect the oscilloscope to TP853 (Pin (5) of
P882) BLUE-OUT.
» Range
» Sweep time : 10 µsec/Div.
3. Call the "SUB-TINT" mode in service mode.
Adjust the "SUB-TINT" bus data to obtain the
waveform shown as Fig. 9.
4. Clear the SERVICE mode.
PROTECTOR OPERATION CHECKING
NO. Adjustment part
Adjusting procedure and conditions
1
BEAM
1. Receive "Monoscope Pattern" signal.
PROTECTOR
2. Set CONTRAST MAX.
3. Set BRIGHT MAX.
4. During the Collector & Emitter of Q883/5/7
short, make sure the protector ON and switch
to standby mode.
2
H, V
1. Receive "Monoscope Pattern" signal.
PROTECTOR
2. Connect output of Bias Box to D607 cathode
(R606 side).
3. Set voltage of Bias Box to 18V and make sure
the protector is not work.
4. Set voltage of Bias Box to 27V, and make sure
the protector is work.
3
OTHER
1. Once finish rectified Electrolytic Capacitor short
PROTECTOR
testing in +B line, check all possible damaged
components on +B line.
(Use random selected set for inspection)
B
A/V INPUT AND OUTPUT CHECKING
NO. Adjustment part
Adjusting procedure and conditions
1
VIDEO AND
1. Receive the "PAL Colour Bar" signal (100%
AUDIO OUTPUT
White Color Bar, Sound 400 Hz 100% Mod
CHECK
C475.)
2. Terminate the Video output with a 75 ohm im-
pedance. Make sure the output is as specified
(1.0 Vp-p ±3 dB).
3. Terminate the Audio output with a 10K ohm
impedance. Make sure the output is as speci-
fied (1.76 Vp-p ±3 dB).
2
VIDEO AND
1. Using the TV/AV key on the remote controller,
AUDIO INPUT
make sure that the modes change in order of
CHECK
TV, AV1, AV2 & TV again and the video & audio
output are according to the input terminal for
each mode.
Waveform and others
SAME LEVEL
: 100 mV/Div. (AC)
(Use Probe 10:1)
W
Y Cy G Mg R B
Fig. 9
Waveform and others
* Select one of Q883/5/7 to do each
short test.
Waveform and others
9-2