ASSEMBLING PROCEDURES OF MAIN PARTS AND CAUTIONS
CAUTION: DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY REPAIRING.
1. R-CONTROL COV. ASSEMBLY
R fan thermo. ass'y
R-temp. control knob
(1) Forming sensor of Damper thermo.
After forming, fix it to the refrigerator.
R air guider A
Defrost timer
RA sealer D
Nylon band
Fan cover
R-C box cover
Damper
thermostat
25
RA sealer A
A sealer thermo. cap.
Figure A-1
Stick thermo.
cap. sealer
+
2
mm
NOTE
Minimum bending radius is R5mm.
There should be no gas leak by reforming of sensor tube.
Figure A-2
13
Damper thermo.
RA sealer C
RA sealer B
Dial sealer
SJ-58L-T2
SJ-63L-T2
SJ-68L-T2