CLW-DIM1, DIMS1, & SLVD1(W/A/B)
Inner Sections of Multiganged Switches
REMOVE INNER SECTIONS
DO NOT REMOVE OUTER SECTIONS
The load capacity must also be derated. The
following charts provide derating information for
various applications.
Derating Information for Incandescent and Tungsten Halogen
Applications
Part
No Side
Number
Removed
-DIM1
1000W
-DIMS1
1000W
-SLVD1
Derating Information for Magnetic Low Voltage Applications
Part
No Side
Number
Removed
-DIM1
1000VA/750W
-DIMS1
1000VA/750W
-SLVD1
*
VA ratings are for input power to the transformer. If you do not
know the input power requirement of the transformer, use the bulb's
wattage rating to determine proper rating.
2. To remove a side section, bend the side section
back and forth with a pair of pliers until the
section breaks off from the mounting plate. Use a
file or sandpaper to remove any excess metal.
Prewire for Master Application
Each device has two Class 2 low voltage wires (plus a
ground wire) that provide a Cresnet connection over
shielded twisted-pair to a Crestron control system. These
wires are routed to the bottom of the device for
connection outside of the wallbox. The low voltage wires
are pulled from each device location to the Crestron
control system or a Crestron connection block device. Use
#22 AWG, twisted, shielded, 2-conductor wire. Wiring
4 • Stand Alone Wall Box Dimmer : CLW-DIM1, DIMS1, & SLVD1
One Side
Two Sides
Removed
Removed
600W
400W
600W
400W
No Derating Necessary
One Side
Two Sides
Removed
Removed
600VA/450W
400VA/300W
600VA/450W
400VA/300W
No Derating Necessary
can be daisy chained, T-tapped, or home run back to the
control system. Refer to the following wiring diagram.
Wiring Diagram of CLW device to Cresnet
NOTE: The GRAY (Cresnet) wires are not polarized.
These wires can be connected to either the Y or Z line on
a Cresnet port.
NOTE: The BLACK wire (Cresnet ground) should not
be grounded with the GREEN (Ground) wire on the
-DIM1/-DIMS1.
NOTE: Crestron recommends using Cresnet-DM cable
for connecting the -DIM1 and -DIMS1 to the Cresnet
network.

Installation

WARNING: Turn off power at the circuit breaker.
Installing with power on can result in serious personal
injury and damage to the device.
*
NOTE: The -DIM1, -DIMS1, and -SLVD1 require a
neutral wire for operation. If no neutral is present, contact
a licensed electrician for installation or refer to the
alternative wiring diagrams described in "Appendix:
Wiring Diagrams" on page 8.
NOTE: The -DIMS1 must be installed in the same
wallbox that contains the connections to the load.
NOTE: New installations should be checked for short
circuits prior to installing the -DIM1, -DIMS1, or
-SLVD1. With power off, close the circuit and restore
power. If the lights do not work or a breaker trips, check
and correct the wiring or fixture (if necessary). Install the
-DIM1, -DIMS1, or -SLVD1 only when the short is no
longer present. The warranty is void if the -DIM1,
-DIMS1, or -SLVD1 is installed and operated with a
shorted load.
When installing a -DIM1 or a -DIMS1 without a slave,
follow the instructions in "Wiring a -DIM(S)1 (No
Slaves)". If wiring a -DIMS1 with a -SLVD1, refer to
Installation Guide – DOC. 6250A