Digital Control DigiTrack Falcon F1 Snelstarthandleiding - Pagina 2

Blader online of download pdf Snelstarthandleiding voor {categorie_naam} Digital Control DigiTrack Falcon F1. Digital Control DigiTrack Falcon F1 6 pagina's.

Steps Required Before Drilling
1.
Optimize and measure active interference.
2.
Select frequency Band 11.
3.
Pair the receiver with the transmitter.
4.
Check for background noise.
5.
Calibrate.
6.
Check Above Ground Range.
Optimize and Measure Active Interference
1.
With the transmitter off, select
Main menu. The FO will show active interference (noise) readings for
Band 11 (and other bands not available on Falcon F1).
Frequency Optimization Results
2.
With the FO results displayed, walk the receiver along the bore path
while observing the noise readings and mark those points where
significant changes occur. If noise levels rise substantially at any point
along the bore, consider re-optimizing at this higher-interference
point.
Select Frequency Band 11
3.
Click to move the selector to Band 11, hold briefly to select, then assign
as the Up band.
It is important to run FO for each new project. FO selects different
frequencies for Band 11 based on the noise at each jobsite.
Your receiver can only detect active interference, not passive
interference. Falcon F1 uses Band 11 in part because frequencies in this
band tend to perform well despite passive interference.
Frequency Optimizer
1. Maximum noise reading
2. Noise
3. Attenuation in effect
4. Band number
5. Selector
6. Pair
7. Exit
- 2 -
(FO) from the