Ook voor Siemens simatic ET 200MP: Handmatig (40 pagina's), Handmatig (24 pagina's), Handmatig (29 pagina's), Handmatig (47 pagina's), Handmatig (26 pagina's), Handmatig (28 pagina's), Handmatig (50 pagina's), Handmatig (34 pagina's), Gebruikershandleiding (44 pagina's), Handmatig (30 pagina's), Handmatig (25 pagina's), Handmatig (42 pagina's), Handmatig (28 pagina's), Handmatig (33 pagina's), Handmatig (49 pagina's), Handmatig (36 pagina's), Handmatig (39 pagina's), Handmatig (28 pagina's), Uitrustingshandleiding (35 pagina's), Uitrustingshandleiding (32 pagina's), Handmatig (29 pagina's), Handmatig (36 pagina's), Uitrustingshandleiding (50 pagina's), Handmatig (45 pagina's)

Siemens simatic ET 200MP Handmatig

Parameter data record 128

Parameter assignment in the user program
You can change the parameters of the module in RUN.
• The parameters are transferred to the technology module with the WRREC instruction via
data record 128. The parameters set with STEP 7 are not changed in the CPU by this
action.
• The technology module then checks the parameters for plausibility.
After a startup, the parameters set with STEP 7 are valid again.
Output parameters: STATUS
If errors occur when transferring parameters with the WRREC instruction, the module
continues operation with the original parameter assignment. In this case, the STATUS output
parameter contains a corresponding error code.
You can find the description of the instruction "WRREC: Write data record" and the error codes
in the information system of the TIA Portal.
Data record structure
The following table shows the structure of the data record 128.
Table A- 1
Parameter data record 128
Bit →
7
Byte
0
Reserved
1)
1
2
3
4
5
Reserved
1)
6
7
8
9
10
28
6
5
1
Major version
Number of following parameter structures = 5
Number of following parameter blocks = 1
Length of the following parameter blocks in bytes = 2
Reserved
Reserved
1)
1)
Number of following parameter blocks = 1
Length of the following parameter blocks in bytes = 2
Number of following parameter blocks = 1
4
3
ID = 0 (common)
Reserved
Reserved
1)
1)
ID = 1 (SD)
Reserved
1)
2
1
Minor version
Reserved
Reserved
1)
1)
Technology Module TM NPU
Equipment Manual, 09/2020, A5E46384784-AA
A
0
Diagnostics:
No load
voltage L+:
0 = Disabled
1 = Enabled