Amendment to the Function Manual
5.2 Formula Split Mode
Remaining Batch
Actual Production
Input Option c
Operator Input:
Constraint
Calculate
Order Size
Actual Production
MaxSizeWithOverProd
Split the order amount in batches of same size and allow overproduction.
From SB:
Configuration/Operator In‐
put:
Constraint:
Input Option a
Operator Input:
Constraint
Batch Size
Calculate
Number of Batches
Actual Production
Input Option b
Operator Input:
40
Q
= max (Q
BatchRemain
Order
Q
= N * Q
+ Q
Prod
Batch
BatchRemain
N, Q
, Q
Batch
BatchRemain
Q
≤ Q
≤ Q
BatchMin
Batch
BatchMax
Q
≤ Q
≤ Q
BatchMin
BatchRemain
1 ≤ N ≤ 100
Q
Order
Q
= N * Q
+ Q
Order
Batch
BatchRemain
Q
= Q
Prod
Order
Q
, Q
RecipeMin
RecipeMax
Q
, Q
BatchMin
BatchMax
Q
≤ Q
≤ Q
RecipeMin
BatchMin
BatchMax
Q
≥ Q
Order
RecipeMin
Q
Order
Q
≤ Q
≤ 100 * Q
BatchMin
Order
Q
= Q
Batch
BatchMax
N
N = Q
/ Q
(rounded up)
Order
BatchMax
Q
= Q
* N
Prod
BatchMax
Q
, Q
Order
Batch
Advanced Process Functions SIMATIC BATCH Integration
- N * Q
, Q
)
Batch
BatchMin
BatchMax
≤ Q
RecipeMax
BatchMax
Function Manual, 07/2016, A5E38719543-AA