Ook voor Siemens Simatic S7-1500: Handmatig (40 pagina's), Handmatig (37 pagina's), Handmatig (47 pagina's), Handmatig (24 pagina's), Handmatig (34 pagina's), Gebruikershandleiding (45 pagina's), Handmatig (27 pagina's), Configuratiehandleiding (20 pagina's), Handmatig (47 pagina's), Handmatig (43 pagina's), Handmatig (48 pagina's), Handmatig (26 pagina's), Handmatig (28 pagina's), Handmatig (50 pagina's), Handmatig (34 pagina's), Gebruikershandleiding (44 pagina's), Handmatig (50 pagina's), Handmatig (30 pagina's), Handmatig (41 pagina's), Handmatig (50 pagina's), Veiligheidsprogrammering Manualline (48 pagina's), Communicatiehandleiding (36 pagina's), Handmatig (40 pagina's), Handmatig (25 pagina's), Handmatig (42 pagina's), Toepassing Beschrijving (50 pagina's), Handmatig (28 pagina's), Handmatig (33 pagina's), Handmatig (49 pagina's), Handmatig (36 pagina's), Handmatig (41 pagina's), Handmatig (46 pagina's), Handmatig (38 pagina's), Handmatig (35 pagina's), Handmatig (39 pagina's), Handmatig (28 pagina's), Handmatig (35 pagina's), Uitrustingshandleiding (35 pagina's), Handmatig (50 pagina's), Uitrustingshandleiding (32 pagina's), Uitrustingshandleiding (38 pagina's), Handmatig (29 pagina's), Uitrustingshandleiding (38 pagina's), Handmatig (34 pagina's), Handmatig (36 pagina's), Uitrustingshandleiding (50 pagina's), Handmatig (45 pagina's)

Siemens Simatic S7-1500 Handmatig

Technical specifications

Product type designation
General information
Hardware version
Firmware version
Engineering with
STEP 7 TIA Portal can be configured/integrated
as of version
Display
Control and display elements
Installation type/mounting
Supply voltage
Type of supply voltage
Input current
Power
Power loss
CPU 1511-1 PN (6ES7511-1AK00-0AB0)
Manual, 01/2013, A5E31264526-AA
Screen diagonal (cm)
Number of buttons
Mode selector switch
Rail mounting possible
Wall/direct mounting possible
Low limit of permitted range (DC)
High limit of permitted range (DC)
Reverse polarity protection
Current consumption (rated value)
Inrush current, max.
I²t
Power consumption from the backplane bus
(balanced)
Incoming power to the backplane bus
Power loss, typ.
6ES7511-1AK00-0AB0
CPU 1511-1 PN
E01
V1.0.0
V12.0
3.45 cm
6
1
Yes
No
24 V DC
19.2 V
28.8 V
Yes
0.7 A
1.9 A; rated value
0.34 A²s
5.5 W
10 W
5.7 W
5
29