Siemens SIMATIC S7-1500R/H Uitrustingshandleiding - Pagina 41
Blader online of download pdf Uitrustingshandleiding voor {categorie_naam} Siemens SIMATIC S7-1500R/H. Siemens SIMATIC S7-1500R/H 44 pagina's. Cpu 1515r-2 pn (6es7515-2rm00-0ab0)
Ook voor Siemens SIMATIC S7-1500R/H: Handmatig (42 pagina's), Handmatig (46 pagina's), Handmatig (45 pagina's), Uitrustingshandleiding (44 pagina's)
Article number
Number of simultaneously active program alarms
Status/control
Forcing
Diagnostic buffer
Traces
Diagnostics indication LED
CPU 1517H-3 PN (6ES7517-3HP00-0AB0)
Equipment Manual, 11/2022, A5E42011886-AD
S7 message functions
Number of login stations for message func
tions, max.
Program alarms
Number of configurable program messages,
max.
Number of loadable program messages in
RUN, max.
•
Number of program alarms
•
Number of alarms for system diagnostics
Test commissioning functions
Joint commission (Team Engineering)
Status block
Single step
Number of breakpoints
•
Status/control variable
•
Variables
•
Number of variables, max.
of which status variables, max.
–
–
of which control variables, max.
Forcing
•
•
Forcing, variables
Number of variables, max.
•
•
present
•
Number of entries, max.
–
of which powerfail-proof
•
Number of configurable Traces
•
Memory size per trace, max.
Interrupts/diagnostics/status information
•
RUN/STOP LED
ERROR LED
•
•
MAINT LED
Connection display LINK TX/RX
•
Technical specifications
6ES7517-3HP00-0AB0
64
Yes
10 000; Program messages are generated by the
"Program_Alarm" block, ProDiag or GRAPH
5 000
2 000
1 000
No
Yes; Up to 16 simultaneously
No
20; Breakpoints are only supported in RUN-Solo
status
Yes
Inputs/outputs, memory bits, DBs, distributed
I/Os, timers, counters
200; per job
200; per job
Yes
Peripheral inputs/outputs
200
Yes
3 200
1 000
8
512 kbyte
Yes
Yes
Yes
Yes
41