Siemens SIMOGEAR 2730 Montage- en bedieningsinstructies - Pagina 32

Blader online of download pdf Montage- en bedieningsinstructies voor {categorie_naam} Siemens SIMOGEAR 2730. Siemens SIMOGEAR 2730 48 pagina's. Geared motor with rotary encoder for safety-relevant applications

Ensuring functional safety
4.4 Commissioning the encoder
Connection assignment, absolute encoder IA 8.5883
Connector viewed from
the outside
 
Connection
Flange socket (SSI) 7
 
 
Connection
 
Flange socket (SSI) 14
 
4.4

Commissioning the encoder

Inadequately qualified personnel
If the encoder is electrically installed by inadequately qualified personnel then the functional
safety can be disabled.
Only qualified personnel are authorized to carry out the work.
These persons must be knowledgeable about:
• Topics relating to functional safety
• Legislation, safety regulations and standards for functional safety
• Content of the detailed operating instructions provided
For commissioning, observe the operating instructions Sendix SIL Encoders for Functional
Safety from Kübler.
30
Signal
Power supply
U
Sensor U
P
1
Sensor pins jum‐
pered in the connec‐
tor
Absolute position values
DATA
DATA,
negated
D+
D-
17
WARNING
1
2
O V
Sensor O V
P
10
4
Sensor pins jum‐
pered in the con‐
nector
CLOCK
CLOCK,
negated
C+
C-
8
9
Operating Instructions, 01/2024, A5E53220857A/RS-AA
0 absolute position value
Increasing absolute values
Diagram showing the signals for clock‐
wise shaft rotation when viewing the
clamping ring and/or the motor drive
end
-
Incremental signals
Inner shield
A+
A-
11
15
16
Not available
-
Other signals
Direction of rotation
Zeros
DIR
SET
2
5
Absolute values are
The absolute value
counted down when
is set to zero when
the input is ener‐
the input is ener‐
gized.
gized.
SIMOGEAR functionally safe rotary encoder
B+
B-
12
13