Radar installation and commissioning
requirements
• A horn antenna will match better than a rod antenna for 6 GHz radar
transmitters.
This will result in lower noise levels on the signal as well as improved accuracy.
• Horn diameter must match the pipe diameter.
A horn diameter that is smaller than the pipe diameter could result in significant
measurement errors due to alternate mode interference.
• Obstructions in the pipe may include the vent connection, slots, or holes.
Orient the radar "e" field towards these obstructions to minimize their interference.
Bypass pipe installation
① Vent
② Align front or back of device with vents.
9
Still pipe installation
① Align front or back of device with still pipe slots.
② Slots