Class: 0x80 COMMAND_CLASS_BATTERY
This class is used to request and report battery levels for a given device. When battery level
is lower than 20% Z-Wave sensor will send a battery warning (value 255) after every wake up
noti cation. A 'battery get' will report the actual value even if below 20 %
Class: 0x86 COMMAND_CLASS_VERSION
This Command Class is used to obtain information about the Z-Wave sensor. The Z-Wave
library type, the Z-Wave protocol version and the application version will be reported.
Class: 0x70 COMMAND_CLASS_CONFIGURATION
Con gure parameters:
0.
Not used
1.
Set to default
Description:
Set all con g values to default values (factory settings). Read
more in
chapter con guration Reset.
Size:
1 byte*
Param1:
if OxFF then set to default
Param2,3,4:
not used
2.
Mode timeout
Description:
The time used in mode 2 to turn the sensor o . This
Time will start running as soon as detection is seen.
Default value:
0x0384 = 900 sec = 15 min
Size:
2 bytes (integer)*
Param1:
the most signi cant byte of the integer
Param2:
the least signi cant byte of the integer
Param3,4:
not used
3.
Switch o time
Description:
The switch o time will start running as soon as mode timeout
is done. Motion sensor is turned on and when movement is de
tected again the mode timeout (cfg param 1) will start running
all over again. When switch o time is done a basic o message is
sent to the associated node.
Default value:
0x0A8C = 2700 sec = 45 min.
Size:
2 bytes (integer)*
Param1:
the most signi cant byte of the integer
Param2:
the least signi cant byte of the integer
Param3,4:
not used
4.
Sensitivity
Description:
the sensitivity of the motion circuit
Default:
0x50 = 80
Size:
1 byte*
Param1:
Sensitivity value between 0 and 127 (values above 127 will be
reported
as the set value but will be handled in SW as 127).
0 is least sensitive and 127 is the most sensitive.
Param2,3,4:
not used
5.
The mode
Description:
The mode that is entered after detection
Default:
0x02
Size:
1 byte*
Param1:
mode 1, 2 or 3.
Mode 1: no detection possible. Battery save mode
Mode 2: normal operation mode: send on after detection and o
after given time no detection.
Mode 3: Z-Wave chip is always on to request e.g. version or
manufacturer id. If mode is 0 or higher then 3, that value will be
reported after a get but will be handled in SW as mode 2.
Param2,3:
not used.
6.
The temperature o set
Description:
A o set for the temperature.
Default:
0x00
Size:
2 bytes*
Param1,2:
A signed integer to determine the o set o the temperature.
Param3,4:
not used.
*if a size is other then given size the frame is ignored totally so con guration values are not
changed
Class: 0x31 COMMAND_CLASS_SENSOR_MULTILEVEL
Sensor_multilevel_get
The Z-Wave sensor Multilevel Command Class is used to get a report from the Z-Wave sensor.
The returned value is the measured temperature inside the housing with 2 decimals.
13