2. You can automatically turn all outlets on using the "All ON
sequence delay" described above. Check the second option
to do this.
3. You can return to the same outlet settings that were used
prior to the power loss. The "All ON sequence delay" will
also be used in this instance. Check the third option for ALL
ON.
User Defined Links
You may link to other power controllers, your own web pages, or
remote web sites by entering up to four URLs and descriptions in the
Setup page. For example, enter "Site Two Power Controller" in the
description field with a URL of "192.168.0.250" These links appear on
the home page.
Network Settings
A fixed IP address, network mask, gateway, and subnet mask must
be entered in this field.
When changing IP addresses, you may need to restart the unit and
your network switch to validate the new IP on an "auto-configuring"
switch port. Be sure to record the new IP address.
Press the "protect" button to lock the network settings. Once locked,
the network settings cannot be changed except by pressing the
physical reset button on the front of the unit.
57& 3DJH
The RTC page allows the administrator to set the internal real time
clock. The clock may be set manually or synchronized to your local
PC time.
Ethernet Power Controller II
10
www.digital-loggers.com
$XWR 3LQJ 3DJH
AutoPing Operation and Settings
AutoPing is an automatic system for rebooting IP equipment without
human intervention. To use AutoPing, first add an IP address. Next,
link that IP address to one or more outlets. Timing settings must also
be considered.
Add IP Address to Auto-Ping
Use this option to specify the address of an IP device you wish to
monitor. After entering the IP address, the settings page will refresh
and you can select the outlets associated with this address. Use the
checkboxes in the AutoPing section to correlate the IP address to one
or more outlets. If communications to the IP address is lost, these
outlets will be rebooted. Four parameters are used for AutoPing
operation:
Time between pings
This is the time between each "ping" check of the IP address. 60
seconds should be useful for most applications.
Ping failures before reboot
This sets the number of failed communications attempts that
must be sequentially detected before a system is rebooted. For
example, when set to 5, the target system must fail to respond 5
times in a row before it is rebooted. Since occasional network
overloads and missed packets can occur during normal network
operation, a number between 5 and 10 pings is recommended.
Ethernet Power Controller II
11