TROUBLESHOOTING

To check the Self-Diagnostic Warning Light, turn on the key and count the number of flashes.
Flash Code/Fault
1. Battery needs
recharging
2. Battery voltage
too Iow
3. Battery voltage
too high
4. Current limit
time-out
5. Brake fault
6. Out of neutral at
power-up
7. Speed VR error
8. Motor volts error
9. Other internal
errors
Impact
on Scooter
Battery charge is running Iow.
Will drive
Recharge the batteries as soon as possible.
Battery charge is empty. Recharge the batteries.
Drive
If the scooter is left off for a few minutes, battery
inhibited
charge might recover enough to allow driving
for a short time.
Battery charge is too high. If a charger is
plugged in, unplug it or turn the Charge/Run
switch to Run. Scooters powered by RHINO
Drive
charge the batteries when travelling down
inhibited
slopes or decelerating. Excessive charging
in this manner can cause this fault. Turn the
scooter power off then on again. If necessary,
reduce speed when descending the slope.
The scooter has drawn too much current for
too long, possibly because the motor has been
over-worked, jammed or stalled. Turn the scooter
Drive
power off, leave for a few minutes, and then
inhibited
turn the power back on again. The controller
has detected a shorted motor. Check the loom
for shorts and check the motor. Contact your
service agent.
Check that the park-brake release lever is in
the engaged position. Check that the motor/
park-brake connector is plugged in firmly. The
park-brake coil or wiring is fauly. Check the
park brake and wiring for open or short circuits
If necessary, unplug the motor/park-brake
Drive
connector and check that all four pins are in the
inhibited
correct position. If this flash code does not
appear until the throttle has been moved out of
neutral, check for a short in the park-brake
circuit. If this flash code appears at power-up,
check for an open circuit in the park-brake
circuit. Contact your service agent.
Thumb lever not in neutral position when turning
key switch on. Return Thumb lever to neutral, turn
Drive
power off, and back on again. Throttle may need
inhibited
to be re-calibrated (see Section 4.2.3). Check
throttle wiring.
Thumb lever or its wiring is faulty. Check for open
Drive
or short circuits. Thumb lever may not be correctly
inhibited
set up. Contact your service agent.
The motor or its wiring is faulty. Check for
Drive
open or shot circuits. Contact your service
inhibited
agent.
Drive
Contact your service agent.
inhibited
15
Instruction Booklet
Notes