Actsoft LMU-5000 Hardware- en installatiehandleiding - Pagina 7

Blader online of download pdf Hardware- en installatiehandleiding voor {categorie_naam} Actsoft LMU-5000. Actsoft LMU-5000 8 pagina's.

Actsoft LMU-5000 Hardware- en installatiehandleiding
Ignition and Inputs
The LMU-5000™ provides up to 7 High/low selectable inputs and one Ignition Sense
input.. These inputs are protected from typical vehicle transients and can be directly
connected to most vehicle level logical inputs from 4 volts up to the vehicle power input
level (typically 12 VDC). Their input impedance is approximately 10k . One of these
inputs is dedicated to sensing the vehicle's ignition status to provide for flexible power
management. The other seven inputs may be used to sense vehicle inputs such as cooling
unit operation, a hidden driver "Panic" switch, taxi on-duty/off-duty meter status or many
others.
The ignition input is pulled to ground through the 10k resistance, where the other inputs
can be configured to be normally High (i.e. pulled to +12v through a 200K10k resistor)
or Low (i.e. pulled to ground through a 100K10k resistor). The diagrams below show
how to connect the inputs in both a high- and low-biased configuration: