5
Maintenance
5.1
Removing the blades for cleaning and replacement
Warning!
!
Disconnect the printer from the electrical outlet.
Caution!
!
Risk of injury. The cutter blades are sharp.
To clean the blades, they must be removed.
1. Disassemble the CSQ cutter from the printer.
2. Loosen screws (1) and remove cover (2) towards the front.
3. Pull the plug (3) of the motor cable out of the socket.
4. Using a 2.5mm hex wrench to turn the axle (4) counterclockwise. The
lower blade (5) is moved down until it can be pulled out.
5. Loosen screws (6). Fix the upper blade (7) while the springs (8) press
against the upper blade (7).
6. Remove the upper blade (7) and make sure that the springs (8) do not fall
out.
1
2
4
5
3
6
7
8
15